November Air Conditioning Repair
Ducted Air Conditioning AC Repair
Location: Coventry
Contract Duration: 4 hours
Project: November Ducted Air Conditioning Leak Investigation 2026
After surviving a very hot UK Summer this AC unit decided it needed a break. Good timing I suppose? A loss of cooling performance often indicates an underlying refrigerant issue, but identifying the exact source requires careful diagnosis and specialist equipment. In this case, a detailed leak investigation was carried out on a domestic ducted air conditioning system, allowing the fault to be accurately located and a clear repair solution provided.
System Overview
The system is a domestic ducted air conditioning installation operating on R410A refrigerant. The customer reported a gradual reduction in cooling performance, longer run times, and difficulty maintaining the desired indoor temperature.
Initial inspection found no obvious signs of damage to external pipework or fittings. The usual suspects of Flare connections are clear, at this point we know its going to be more than a spanner up and gas up. Time to crack open all the panels.
Fault Diagnosis
To pinpoint the source of the refrigerant loss, the indoor ducted unit was accessed, and an electronic refrigerant leak detector was used to systematically inspect all accessible pipework, joints, and coil surfaces.
During testing, the leak detector produced a strong positive response across the evaporator coil area, confirming the presence of a refrigerant leak within the indoor coil assembly. Visual inspection of the coil revealed areas of corrosion consistent with long-term refrigerant leakage.
The investigation confirmed that the evaporator coil had developed a refrigerant leak and was the primary cause of the system's loss of charge and reduced performance.
Assessment of Repair Options
Due to the location and condition of the leak, a permanent repair to the coil was deemed impractical and unlikely to provide long-term reliability. The affected section is not economically repairable, and any temporary repair would carry a significant risk of future refrigerant loss.
Fortunately, replacement coils remain available for this model, allowing a full and reliable repair to be completed without the need for total system replacement.
Recommended Repair
The recommended course of action is:
- Supply and install a replacement evaporator coil.
- Recover remaining R410A refrigerant in accordance with current regulations.
- Remove the failed coil assembly.
- Install the new manufacturer-compatible coil.
- Pressure test the system with nitrogen.
- Evacuate the system to remove moisture and non-condensables.
- Recharge the system with the correct quantity of R410A refrigerant.
- Commission and performance test the system.
Outcome
The source of the refrigerant leak has been successfully identified using electronic leak detection equipment. While the existing coil is beyond practical repair, replacement parts are available, making restoration of the system a viable and cost-effective option.
Once the new coil is installed and the system recommissioned, the ducted air conditioning system will be returned to normal operation with full cooling performance restored.
Need air conditioning repairs or leak detection services? We provide professional fault diagnosis, refrigerant leak detection, repairs, and replacement of components for domestic and commercial air conditioning systems. Contact us today for expert advice and reliable service.
